Filters
Question type

Study Flashcards

Measurements from one biofeedback unit can be reliably compared to another brand of biofeedback unit.

Correct Answer

verifed

verified

The integrity of the electromyographic biofeedback signal depends on the number of filters used,with the signal becoming more precise with more filters.

Correct Answer

verifed

verified

Which of the following modalities does not deliver energy to the body?


A) Ice pack
B) Moist heat pack
C) Ultrasound
D) Electromyographic biofeedback

Correct Answer

verifed

verified

When using biofeedback to facilitate an isometric contraction,how many contractions should the treatment be limited to if the muscle group is severely atrophied?


A) 5 contractions
B) 5 to 10 contractions
C) 10 to 15 contractions
D) 20 contractions

Correct Answer

verifed

verified

What step in the electromyographic biofeedback signal process involves taking the absolute value of the negative electrical activity and making it a mathematically positive number?


A) Amplification
B) Integration
C) Rectification
D) Identification

Correct Answer

verifed

verified

What type of biofeedback measures the amount of light reflected by the subcutaneous tissues?


A) Mechanomyographic
B) Electromyographic
C) Galvanic skin response
D) Photoplethysmography

Correct Answer

verifed

verified

The most sensitive EMG surface monitors have electrodes made with what metal?


A) Silver
B) Zinc
C) Gold
D) Copper

Correct Answer

verifed

verified

A

What biofeedback parameter identifies a target range for electromyographic activity?


A) Alarm
B) Output
C) Sensitivity range
D) Tuner

Correct Answer

verifed

verified

Which of the following is considered an initial result of biofeedback and not a secondary result from the initial?


A) Facilitates reeducation
B) Increases muscular strength
C) Increases range of motion
D) Reduces pain

Correct Answer

verifed

verified

A

The efficacy for electromyographic biofeedback is clinically well accepted for what scenario?


A) Reeducating muscle
B) Increasing strength
C) Decreasing pain
D) Reducing edema

Correct Answer

verifed

verified

Placement of treatment electrodes from one treatment to another will affect the reliability of a biofeedback measurement.

Correct Answer

verifed

verified

In which scenarios is the use of electromyographic biofeedback indicated? Select all that apply.


A) Decrease muscle spasm of erector spinae
B) Promote systemic relaxation
C) Regain neuromuscular control of the vastus medialis oblique
D) Facilitate contraction of the biceps femoris
E) Treatment of a second-degree strain to the gastrocnemius

Correct Answer

verifed

verified

A,B,C,D

Which statement is true concerning the placement of surface electrodes when using electromyographic biofeedback?


A) The electrodes should be placed about 3 cm apart.
B) The closer the electrodes,the stronger the signal.
C) The farther apart the electrodes,the weaker the signal.
D) Electrodes placed farther apart will have better reliability.

Correct Answer

verifed

verified

What is the correct order of electromyographic biofeedback signal processing?


A) Identify; amplify; rectify; integrate; output
B) Identify; rectify; amplify; integrate; output
C) Identify; amplify; integrate; rectify; output
D) Identify; integrate; amplify; rectify; output

Correct Answer

verifed

verified

Biofeedback is used to measure biophysical properties.Which of the following represents uses for the feedback that is measured? Select all that apply.


A) Muscle reeducation
B) Facilitation of muscle relaxation
C) Control blood pressure
D) Control heart rate
E) Control respirations

Correct Answer

verifed

verified

The benefits of biofeedback can be enhanced by performing which of the following? Select all that apply.


A) Educating the patient on the concept of biofeedback
B) Incorporating learning strategies
C) Setting patient goals
D) Providing verbal feedback from the clinician while producing muscle contraction
E) Educating the patient on the physiology of muscle contractions

Correct Answer

verifed

verified

When compared to standard flexibility exercises,the use of relaxation biofeedback has been shown to significantly increase flexibility in healthy individuals.

Correct Answer

verifed

verified

What term is commonly used to represent the small amount of energy that is absorbed by the body due to its bombardment by electromagnetic energy?


A) Noise
B) Interference
C) Static
D) Resistance

Correct Answer

verifed

verified

Which of the following are likely reasons that someone post-ACL surgery would not be able to contract their vastus medialis oblique?


A) Swelling and pain
B) Pain and denervation
C) Denervation,disuse atrophy,and swelling
D) Swelling,pain,and disuse atrophy

Correct Answer

verifed

verified

According to the practical evidence,when is it most beneficial to incorporate electromyographic biofeedback in a neuromuscular rehabilitation?


A) Early on
B) Middle of the program
C) Toward the end of the program
D) Timing of application does not alter the benefits of biofeedback.

Correct Answer

verifed

verified

Showing 1 - 20 of 20

Related Exams

Show Answer