All floor drains require a 4" deep seal trap.

Correct Answer

verifed

verified

False

The ____ is the vertical distance between the top of the trap dip and the crown weir.


A) developed length
B) inlet
C) outlet
D) trap seal

Correct Answer

verifed

verified

Slip joint-type traps must be in accessible locations.

Correct Answer

verifed

verified

True

A trap primer is a device that maintains the water seal in a trap.

Correct Answer

verifed

verified

Most of the causes of trap seal loss can be minimized or prevented by proper drainage and venting installations.

Correct Answer

verifed

verified

Urinals are required to have integral traps.

Correct Answer

verifed

verified

The loss of trap seal caused by the back and forth movement of water sending the seal water over the crow weir is called ____.


A) momentum
B) oscillation
C) aspiration
D) capillary action

Correct Answer

verifed

verified

A plumbing trap is a device that prevents the passage of sewer gas into the structure.

Correct Answer

verifed

verified

Most codes limit trap seal depth to a maximum of ____.


A) 2 inches
B) 3 inches
C) 4 inches
D) 5 inches

Correct Answer

verifed

verified

Traps should be one piece, without joints, for maximum trap integrity.

Correct Answer

verifed

verified

____ is the loss of trap seal caused when water in the trap changes from liquid to vapor state and is lost from the trap.


A) Evaporation
B) Condensation
C) Aspiration
D) Oscillation

Correct Answer

verifed

verified

Evaporation is a cause of trap seal loss that cannot be prevented by correct venting.

Correct Answer

verifed

verified

The typical trap seal is ____ deep.


A) 1inchs
B) 2 inches
C) 2inches
D) 3 inches

Correct Answer

verifed

verified

Which of the following is a permitted trap?


A) ball trap
B) partition trap
C) P-trap
D) S-trap

Correct Answer

verifed

verified

Except for interceptors, the trap seal should be between ____ and ____.


A) 1 inch, 3 inches
B) 2 inches, 4 inches
C) 3 inches, 5 inches
D) 4 inches, 6 inches

Correct Answer

verifed

verified

B

____ is the loss of trap seal from negative pressure at the trap outlet.


A) Oscillation
B) Momentum
C) Capillary action
D) Siphonage

Correct Answer

verifed

verified

Traps should always be smaller than the fixture outlet.

Correct Answer

verifed

verified

A device that periodically adds water to a trap is a ____.


A) P-trap
B) hydraulic pump
C) S-trap
D) trap primer

Correct Answer

verifed

verified

Another name for a building trap is a ____.


A) running trap
B) drum trap
C) partition trap
D) bell trap

Correct Answer

verifed

verified

Showing 1 - 19 of 19