Filters
Question type

Study Flashcards

In MSCT, the slice thickness is not determined by which factor?


A) Volume coverage
B) Beam width in the z-axis
C) Pitch
D) Shape and width of the reconstruction filter

Correct Answer

verifed

verified

The CT detector consists of each of these components except:


A) radiation sensor.
B) photodiodes.
C) analog to digital converter (ADC) .
D) high-frequency generator.

Correct Answer

verifed

verified

A

Which of the following is not a parameter of image quality?


A) Spatial resolution
B) Patient dose
C) Contrast resolution
D) Noise

Correct Answer

verifed

verified

In an MSCT scanner, what type of algorithm can be used if the number of detector rows is small?


A) Cone-beam reconstruction
B) Fan-beam reconstruction
C) x-axis reconstruction
D) z-axis reconstruction

Correct Answer

verifed

verified

Which of the following is not a physical property of detectors?


A) High luminescence efficiency
B) Large dynamic range
C) Small afterglow
D) Recyclable value

Correct Answer

verifed

verified

Which method of CT scanning does interscan delay occurs?


A) Single-slice CT (SSCT) scanner
B) Slice-by-slice CT scanner
C) Volume CT scanner
D) Multislice CT (MSCT) scanner

Correct Answer

verifed

verified

What is the term used to describe the flipped view used for interpolated reconstruction?


A) Complementary data
B) Opposed data
C) Opposite data
D) Reciprocal data

Correct Answer

verifed

verified

New capabilities created as a result of the creation of spiral/helical CT include each of the following applications except:


A) CT endoscopy.
B) real-time CT fluoroscopy.
C) stroke imaging.
D) CT angiography.

Correct Answer

verifed

verified

What year was the first computed tomography (CT) scanner able to perform volume data acquisition introduced?


A) 1988
B) 1989
C) 1990
D) 1991

Correct Answer

verifed

verified

An early pioneer in the development of the technique of volume rendering was Dr. Willi A. Kalender.

Correct Answer

verifed

verified

True

The radiation sensors convert ___________ to ___________.


A) light; X-ray photons
B) X-ray photons; light
C) light; electrical signals
D) electric signals; light

Correct Answer

verifed

verified

B

A pitch greater than 1 will result in an increased dose.

Correct Answer

verifed

verified

The computer systems of MSCT scanners have hardware that provides all of the following except:


A) high-speed processing.
B) image communication.
C) image reconstruction.
D) postprocessing operations.

Correct Answer

verifed

verified

If the X-ray prepatient collimation width is 24 cm and the scanner has a four-row detector array, what is the detector row collimation?


A) 4 mm
B) 5 mm
C) 6 mm
D) 7 mm

Correct Answer

verifed

verified

All the following are problems that can occur from data acquisition with spiral geometry except:


A) localization of a particular slice is difficult.
B) inconsistent projection data.
C) increased patient dose.
D) streak artifacts can occur.

Correct Answer

verifed

verified

All of the following are requirements for volume scanning except:


A) continuous couch movement.
B) increased cooling capacity.
C) slip-ring technology.
D) tube memory.

Correct Answer

verifed

verified

What term is used to describe the resorting of the 3D data collected from the cone-beam acquisition to a set of 2D fan-beam data?


A) Binning
B) Rebinning
C) Reformatting
D) Sampling

Correct Answer

verifed

verified

All of these components are rotating parts of the spiral/helical CT scanner except the:


A) X-ray tube.
B) high-voltage generator.
C) detectors.
D) front-end memory.

Correct Answer

verifed

verified

What is the ideal pitch in spiral/helical CT?


A) 1
B) 2
C) 3
D) 4

Correct Answer

verifed

verified

The first step in volume scanning is analog to digital conversion.

Correct Answer

verifed

verified

Showing 1 - 20 of 60

Related Exams

Show Answer