Each occupant must have ready access to ____ protecting the conductors supplying that occupancy.


A) primary feeders
B) all overcurrent devices
C) panel boxes
D) service laterals

Correct Answer

verifed

verified

Conductors must have ____ and sufficient ampacity to carry the current for the load as calculated.


A) sufficient length
B) adequate insulation
C) adequate mechanical strength
D) definitive markings

Correct Answer

verifed

verified

Skin effect and induction change the resistance in alternating-current (ac) circuits, therefore resistance of a conductor is ____.


A) slightly lower in an ac circuit
B) reciprocally lower in a dc circuit
C) slightly higher in an ac circuit
D) reciprocally higher in a dc circuit

Correct Answer

verifed

verified

C

The larger the circular mil area of a conductor, the ____.


A) greater the resistance
B) more insulation required
C) more flexible the conductor
D) smaller the resistance

Correct Answer

verifed

verified

____ is defined as the underground conductors between the utility electric supply system and the service point.


A) Service lateral
B) Primary branch
C) Ancillary service
D) Connection branch

Correct Answer

verifed

verified

Service conductors supplying a building (or other structure) shall not ____.


A) terminate in a panel
B) be enclosed in a six-gang enclosure
C) pass through the interior of another building
D) have less than two disconnects

Correct Answer

verifed

verified

C

If the load requirements of a single-phase installation are greater than the serving agency normally supplies through one service, ____ are permitted.


A) additional agencies
B) multiple branches
C) service disconnects
D) multiple services

Correct Answer

verifed

verified

A drip loop's lowest point has a minimum vertical clearance of ____ ft.


A) 4
B) 6
C) 8
D) 10

Correct Answer

verifed

verified

The recommended voltage drop for a branch circuit is ____ % or less.


A) 1
B) 5
C) 3
D) 7

Correct Answer

verifed

verified

General receptacle installation provisions for multifamily dwellings are almost identical to those for ____.


A) commercial properties
B) garage facilities
C) dual-family dwellings
D) one-family dwellings

Correct Answer

verifed

verified

All electric equipment must be ____ to allow ready and safe equipment operation and maintenance.


A) externally grounded
B) surrounded by sufficient unobstructed space
C) enclosed within a metal cabinet
D) surrounded by at least 2 ft of ventilation space

Correct Answer

verifed

verified

The maximum distance to any receptacle, measured horizontally along the wall line, is ____ in.


A) 6
B) 12
C) 18
D) 24

Correct Answer

verifed

verified

The vertical clearance above roof level must be maintained for a distance of at least ____ ft from all edges of the roof.


A) 3
B) 4
C) 6
D) 8

Correct Answer

verifed

verified

Dwelling-unit branch circuits shall supply only loads within, or associated only with, ____.


A) dwellings in that vertical line
B) a parallel unit
C) other branch circuits
D) that dwelling unit

Correct Answer

verifed

verified

All 125-volt, single-phase, 15- and 20-ampere dwelling unit outdoor receptacles must have ____.


A) separate circuit breakers
B) interior grounding
C) GFCI protection
D) exterior grounding

Correct Answer

verifed

verified

A minimum of ____ wall switch-controlled lighting outlet(s) is (are) required for dwelling hallways.


A) one
B) two
C) three
D) four

Correct Answer

verifed

verified

A single-phase feeder (or branch circuit) conductor will have a total resistance ____ that of one conductor.


A) half
B) twice
C) three times
D) four times

Correct Answer

verifed

verified

The conductors and equipment that deliver energy from the electricity supply system to the wiring system of the premises are called the ____.


A) main feeders
B) service
C) central lines
D) primary carriers

Correct Answer

verifed

verified

Kitchen receptacles not serving countertops (such as receptacles behind refrigerators) ____ unless they are installed within 6 ft of the outside edge of the sink.


A) must be on a separate branch circuit
B) require a dual phase leader
C) do not require GFCI protection
D) are not counted towards total load

Correct Answer

verifed

verified

C

____ is the maximum number of disconnects per service grouped in any one location.


A) Two
B) Three
C) Six
D) Nine

Correct Answer

verifed

verified

Showing 1 - 20 of 25