Correct Answer
verified
Multiple Choice
A) M1
B) M2
C) M3
D) all of these
Correct Answer
verified
Multiple Choice
A) when the relay coil is energized,there is a time delay in closing.
B) when the relay coil is energized,there is a time delay in opening.
C) when the relay coil is de-energized,there is a time delay before the contact opens.
D) when the relay coil is de-energized,there is a time delay before the contact closes.
Correct Answer
verified
Multiple Choice
A) electromagnetic pneumatic timer.
B) electromechanical motor-driven timer.
C) off-delay timer.
D) on-delay timer.
Correct Answer
verified
Multiple Choice
A) 3 seconds
B) 4 seconds
C) 20 seconds
D) 200 seconds
Correct Answer
verified
True/False
Correct Answer
verified
Multiple Choice
A) AC time must be greater than the PR time.
B) PR time must be greater than the AC time.
C) AC time must equal the PR time.
D) none of these.
Correct Answer
verified
Multiple Choice
A) Accumulated time.
B) Preset time.
C) Timer address.
D) Time base.
Correct Answer
verified
Multiple Choice
A) power is applied.
B) input A is closed.
C) the timer is accumulating time.
D) the accumulated value equals the preset value.
Correct Answer
verified
Multiple Choice
A) 0
B) 200
C) T4:3
D) 0.1
Correct Answer
verified
Multiple Choice
A) ON,OFF
B) OFF,ON
C) instantaneous,timed
D) timed,instantaneous
Correct Answer
verified
True/False
Correct Answer
verified
Multiple Choice
A) TON timer can maintain its accumulated time on loss of power or logic continuity.
B) TOF timer can maintain its accumulated time on loss of power or logic continuity.
C) TOF timer begins timing when logic continuity to the timing rung is lost.
D) TON timer begins timing when logic continuity to the timing rung is lost.
Correct Answer
verified
True/False
Correct Answer
verified
Multiple Choice
A) after the coil is energized.
B) after the coil is de-energized.
C) after power is applied to the circuit.
D) either a or b.
Correct Answer
verified
Multiple Choice
A) retentive on-delay.
B) retentive off-delay.
C) nonretentive off-delay
D) nonretentive on-delay.
Correct Answer
verified
Multiple Choice
A) power is applied.
B) input A is closed.
C) the timer is accumulating time.
D) the accumulated value equals the preset value.
Correct Answer
verified
True/False
Correct Answer
verified
Multiple Choice
A) Accumulated time.
B) Preset time.
C) Timer address.
D) Time base.
Correct Answer
verified
Multiple Choice
A) PB1 is closed.
B) PB2 is closed.
C) PB1 is open.
D) PB2 is open.
Correct Answer
verified
Showing 21 - 40 of 58