An RTO timer retains the present accumulated value when the rung goes false.

Correct Answer

verifed

verified

For the programmed timer circuit shown,when the switch is initially closed motor(s) _____ start(s) immediately. For the programmed timer circuit shown,when the switch is initially closed motor(s) _____ start(s) immediately.   A) M1 B) M2 C) M3 D) all of these


A) M1
B) M2
C) M3
D) all of these

Correct Answer

verifed

verified

The relay contact drawn is designed to operate so that: The relay contact drawn is designed to operate so that:   A) when the relay coil is energized,there is a time delay in closing. B) when the relay coil is energized,there is a time delay in opening. C) when the relay coil is de-energized,there is a time delay before the contact opens. D) when the relay coil is de-energized,there is a time delay before the contact closes.


A) when the relay coil is energized,there is a time delay in closing.
B) when the relay coil is energized,there is a time delay in opening.
C) when the relay coil is de-energized,there is a time delay before the contact opens.
D) when the relay coil is de-energized,there is a time delay before the contact closes.

Correct Answer

verifed

verified

The operation of a PLC retentive timer is similar to that of an:


A) electromagnetic pneumatic timer.
B) electromechanical motor-driven timer.
C) off-delay timer.
D) on-delay timer.

Correct Answer

verifed

verified

The on-delay timed period for the timer shown would be: The on-delay timed period for the timer shown would be:   A) 3 seconds B) 4 seconds C) 20 seconds D) 200 seconds


A) 3 seconds
B) 4 seconds
C) 20 seconds
D) 200 seconds

Correct Answer

verifed

verified

For the timer relay contact shown,when the relay coil is energized,there is a time delay before the contact closes. For the timer relay contact shown,when the relay coil is energized,there is a time delay before the contact closes.

Correct Answer

verifed

verified

To reset a retentive timer,the:


A) AC time must be greater than the PR time.
B) PR time must be greater than the AC time.
C) AC time must equal the PR time.
D) none of these.

Correct Answer

verifed

verified

Which one of the following timer parameters determines the time duration for the timing circuit?


A) Accumulated time.
B) Preset time.
C) Timer address.
D) Time base.

Correct Answer

verifed

verified

For the timer program shown,output C is switched ON when: For the timer program shown,output C is switched ON when:   A) power is applied. B) input A is closed. C) the timer is accumulating time. D) the accumulated value equals the preset value.


A) power is applied.
B) input A is closed.
C) the timer is accumulating time.
D) the accumulated value equals the preset value.

Correct Answer

verifed

verified

For the on-delay timer instruction shown the timer number is: For the on-delay timer instruction shown the timer number is:   A) 0 B) 200 C) T4:3 D) 0.1


A) 0
B) 200
C) T4:3
D) 0.1

Correct Answer

verifed

verified

For the hardwired timer circuit shown,contact TD-1 is the ____ contact and TD-2 is the ____ contact. For the hardwired timer circuit shown,contact TD-1 is the ____ contact and TD-2 is the ____ contact.   A) ON,OFF B) OFF,ON C) instantaneous,timed D) timed,instantaneous


A) ON,OFF
B) OFF,ON
C) instantaneous,timed
D) timed,instantaneous

Correct Answer

verifed

verified

A lamp is to be switched off 10 s after a switch has been switched from it's on to off position.The most directly applicable timer to use would be the off-delay nonretentive timer.

Correct Answer

verifed

verified

The main difference between a TON and TOF timer is that the:


A) TON timer can maintain its accumulated time on loss of power or logic continuity.
B) TOF timer can maintain its accumulated time on loss of power or logic continuity.
C) TOF timer begins timing when logic continuity to the timing rung is lost.
D) TON timer begins timing when logic continuity to the timing rung is lost.

Correct Answer

verifed

verified

For the timer relay contact shown,when the relay coil is de-energized,there is a time delay before the contact closes. For the timer relay contact shown,when the relay coil is de-energized,there is a time delay before the contact closes.

Correct Answer

verifed

verified

Certain contacts of a mechanical timing relay are designed to operate at a preset time interval:


A) after the coil is energized.
B) after the coil is de-energized.
C) after power is applied to the circuit.
D) either a or b.

Correct Answer

verifed

verified

The type of timer program shown is a: The type of timer program shown is a:   A) retentive on-delay. B) retentive off-delay. C) nonretentive off-delay D) nonretentive on-delay.


A) retentive on-delay.
B) retentive off-delay.
C) nonretentive off-delay
D) nonretentive on-delay.

Correct Answer

verifed

verified

For the timer program shown,output D is switched ON when: For the timer program shown,output D is switched ON when:   A) power is applied. B) input A is closed. C) the timer is accumulating time. D) the accumulated value equals the preset value.


A) power is applied.
B) input A is closed.
C) the timer is accumulating time.
D) the accumulated value equals the preset value.

Correct Answer

verifed

verified

Timer instructions are found on all PLCs manufactured today.

Correct Answer

verifed

verified

Which one of the following timer parameters determines the accuracy of the timer?


A) Accumulated time.
B) Preset time.
C) Timer address.
D) Time base.

Correct Answer

verifed

verified

For the program shown,the timer accumulated time is set to zero anytime: For the program shown,the timer accumulated time is set to zero anytime:   A) PB1 is closed. B) PB2 is closed. C) PB1 is open. D) PB2 is open.


A) PB1 is closed.
B) PB2 is closed.
C) PB1 is open.
D) PB2 is open.

Correct Answer

verifed

verified

Showing 21 - 40 of 58